IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 0130M00075 Low Pressure Switch is a genuine OEM loss-of-charge safety control for the Goodman WGPH4536AMAB packaged air conditioner and compatible models. Installed on the suction (low) side of the refrigerant circuit, it opens the compressor control circuit when suction pressure drops too low — guarding against compressor damage from a refrigerant leak, low charge, or a restricted metering device.
The OEM 0130M00075 ships with Goodman's specified cut-out and cut-in set points already calibrated. Universal aftermarket switches frequently use different trip points and fittings, which can cause short-cycling or fail to protect the compressor during a slow leak. OEM is the safe choice for this safety device.
Moderate. Power must be disconnected and the switch connects to a low-side refrigerant port plus two low-voltage terminals. Some setups require an EPA-certified technician for refrigerant access. Allow 20–40 minutes.