The Goodman 0130M00087 is an OEM low-pressure (loss-of-charge) switch for DCC0720153VWDFAA 6-ton (72,000 BTU) package air conditioners. It opens the control circuit when suction pressure drops below the factory setpoint, protecting the compressor against a low refrigerant charge, a frozen coil, or restricted suction. Symptoms of a faulty switch include short-cycling, low-pressure lockouts in cold weather, or a compressor that never starts.
The OEM 0130M00087 ships with Goodman's exact trip pressures, fitting, and connector for a plug-and-play swap. Generic switches with different setpoints can mask a real charge problem or nuisance-trip in mild conditions. For loss-of-charge protection, OEM is recommended.
Advanced. Mounts to the pressurized suction line. Confirm whether your unit uses a self-sealing Schrader fitting or requires recovery before removal. Disconnect power first; a licensed HVAC technician should perform refrigerant-side work.