IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 0130M00075 Low Pressure Switch is a genuine OEM safety control engineered for the APH1642M41AB heat pump and matching Goodman/Amana units. Installed on the suction (low) side of the refrigerant circuit, it senses when pressure drops too low — from a refrigerant leak, undercharge, or blocked metering device — and interrupts the compressor circuit to prevent it from running dry and overheating. It is the system's first line of defense against expensive loss-of-charge compressor failure.
As a calibrated safety switch, the OEM 0130M00075 opens and closes at the precise pressures Goodman specified for this heat pump. Aftermarket switches with generic set points risk nuisance lockouts in cold weather or failing to protect the compressor during a slow leak. Genuine OEM ensures the right thresholds and a leak-free fit.
Moderate (3 of 5). Quick-connect versions install without recovering refrigerant — power down the unit, transfer the leads, and verify the port seats fully. Threaded-line versions call for an EPA-certified technician. Budget 30–60 minutes.