IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 0130M00075 is a genuine OEM low-pressure switch for the APH1524M41CA packaged heat pump and compatible R-410A APH-series units. Installed on the low (suction) side of the refrigerant circuit, it opens the control circuit when suction pressure drops too low — the classic loss-of-charge or frozen-coil condition — shutting the compressor down before it runs starved. It auto-resets once pressure recovers.
The OEM 0130M00075 is calibrated to Goodman's specified cut-out and cut-in pressures for this system. Generic switches with different setpoints can cause short-cycling or leave the compressor unprotected during a slow leak. Because it guards a costly compressor, the OEM part is the reliable choice.
Difficulty: Moderate (3/5). On Schrader-port versions you can swap the switch without recovering refrigerant — cut power, confirm pressures on a manifold, and transfer the wiring. Brazed-port versions require recovery, replacement, and evacuation by a licensed technician.