IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 0130M00075 Low Pressure Switch is a genuine OEM refrigerant safety control engineered for the APH1524M41AD packaged heat pump. This automatic-reset switch monitors suction-line pressure and interrupts the compressor circuit whenever refrigerant pressure drops below the factory threshold — protecting the compressor from damage caused by low charge, restricted airflow, or a failed metering device. When your system short-cycles, trips on a safety fault, or won't run in heat-pump mode, a faulty low pressure switch is a common and inexpensive cause.
The genuine OEM 0130M00075 is calibrated to Goodman's exact cut-in and cut-out pressures, guaranteeing correct compressor protection and preserving your equipment warranty. Universal aftermarket switches often use different trip points or terminal styles, risking nuisance trips or an unprotected compressor. For a safety-rated control, OEM is strongly recommended.
Moderate — replacement requires reclaiming or isolating refrigerant unless the switch is on a Schrader-style port. Best performed by an EPA-certified HVAC technician. Always disconnect power and verify system pressure before servicing.