IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 0130M00075 Low Pressure Switch is a genuine OEM safety control for the APH1436H41DC Amana/Goodman package heat pump. It monitors suction-side refrigerant pressure and opens the control circuit when pressure drops too low — typically from a loss of charge, a leak, or restricted flow — preventing the compressor from running in a starved condition that would cause overheating and failure.
The OEM 0130M00075 carries the precise low-side cut-out and reset setpoints matched to your system's refrigerant and control logic. A generic switch with mismatched setpoints can lock out the unit in normal operation or, worse, let the compressor run dry. On a protective control, OEM calibration is not a place to cut corners.
Easy–Moderate (2/5). Schrader-mounted versions swap in minutes; brazed connections require refrigerant recovery and brazing. Always de-energize the unit at the disconnect and follow EPA recovery procedures if the sealed system is opened.
Fits Goodman/Amana APH1436H41DC. Confirm model, serial, and connection type before ordering. Questions? info@nationalhvacparts.com.