IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 0130M00075 is a genuine OEM low-pressure switch designed as a direct-fit replacement for the APH1424M41AA heat pump. Installed on the low (suction) side of the refrigerant circuit, this normally-closed switch opens the control circuit when suction pressure drops too low — indicating a loss of charge, a leak, or a restriction — protecting the compressor from running with inadequate refrigerant and cooling.
The OEM switch is calibrated to Goodman's specified low-side cut-out and reset pressures, and pairs correctly with the high-pressure switch (0130M00074) in the same safety string. Generic replacements risk nuisance trips in cold weather or failure to protect during a slow leak, plus fitting mismatches. OEM keeps the protection loop accurate.
Rating: Moderate. Schrader-fitting versions can often be replaced without recovering the charge; brazed versions require EPA 608 certification and refrigerant handling. Always disconnect power first, confirm the connection type, and follow Goodman documentation. Defer charge-affecting work to a licensed HVAC technician.