IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 0130M00075 Low Pressure Switch is a genuine OEM safety control for the APH1342M41CA heat pump. Installed on the suction (low) side of the refrigerant circuit, it opens the low-voltage control circuit and stops the compressor when suction pressure drops too low — guarding against loss-of-charge, refrigerant leaks, and frozen-coil conditions that would otherwise damage the compressor.
The OEM low pressure switch is set to Goodman's exact cut-out and reset points for this platform, so it protects against loss of charge without nuisance trips during normal low-ambient operation. Generic switches with the wrong set points either lock out unnecessarily or fail to protect the compressor. OEM calibration is worth it on a safety control.
Moderate (3/5). Best left to an HVAC technician because it ties into the sealed system. Isolate or recover refrigerant as required by the port type, kill power at the disconnect, install the new switch, then leak-check and confirm the low-pressure safety functions on start-up.