IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The 0130M00075 is a genuine Goodman low-pressure (loss-of-charge) safety switch for the APH1630H41AB heat pump and compatible R-410A systems. Installed on the low (suction) side, it interrupts the control circuit when suction pressure drops too far — a sign of refrigerant undercharge, a leak, or a restricted line — preventing the compressor from running dry and self-destructing.
The OEM 0130M00075 is factory-calibrated to Goodman's low-side trip points. Aftermarket equivalents frequently mis-trip, either failing to protect the compressor during a slow leak or nuisance-tripping in cold-weather heat-pump operation. On a protective device, OEM is the safe choice.
Moderate — involves the sealed refrigerant system. Recover refrigerant and disconnect power first; installation is best handled by an EPA 608–certified technician.