The 0130F00008S is a genuine Goodman/Amana hot surface ignitor (HSI) built as a direct-fit replacement for the ADV80905CXBB gas furnace and compatible Goodman/Amana models. The hot surface ignitor is the most common no-heat failure on modern furnaces: the control board energizes the element, it glows red-hot, and it lights the burners at the start of each heat cycle. Ignitors are brittle and degrade with every cycle — a cracked or aged element causes intermittent no-light, hard starts, and ignition lockout codes.
The OEM 0130F00008S arrives with the correct plug/connector, bracket, and element resistance the Goodman control board expects, so it drops in and lights on the first cycle. Generic universal ignitor kits require adapting the harness and getting the mounting depth right relative to the burner flame — a misplaced ignitor cracks early or fails to prove flame. For reliable ignition, OEM is the recommended choice.
Typically 15–25 minutes. Cut furnace power at the breaker, unplug the old ignitor, unscrew the mounting bracket, and install the new one — handle only by the ceramic base, never touch the element, as skin oils shorten its life. Reconnect, restore power, and watch for a clean glow and burner light-off. If you are unsure, use a licensed HVAC technician.