IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The genuine OEM Goodman 0130M00074 is a high-pressure cut-off (limit) switch for the Goodman WPH4324AHAB packaged unit and compatible systems. Wired into the safety circuit, it opens when refrigerant discharge pressure exceeds the factory trip point — shutting down the compressor to prevent damage from a blocked condenser, overcharge, or fan failure. A weak or failed switch causes nuisance lockouts or, worse, leaves the compressor unprotected.
The OEM 0130M00074 is calibrated to Goodman's exact cut-out and reset pressures and uses the correct port fitting and terminals. Generic switches with different trip settings can trip early (nuisance shutdowns) or too late (no protection). For a safety device, always use the OEM-spec part.
Moderate — the switch mounts on a Schrader-style port so no refrigerant recovery is typically needed; disconnect the two wire leads, thread out the old switch, and install the new one. About 20–30 minutes. Kill power before servicing.