IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 0130M00074 is a genuine OEM high-pressure cut-off switch for the WPH4336AMAB packaged heat pump and compatible Goodman/Amana systems. This safety control opens the circuit when refrigerant discharge pressure climbs too high — protecting the compressor from damage caused by restricted airflow, a dirty condenser coil, or overcharge. A tripped or failed high-pressure switch is a frequent cause of a compressor that won't run or repeatedly locks out.
This genuine Goodman switch is factory-set to the correct cut-out and cut-in pressures for your system. Generic pressure switches often carry different trip points, which can either allow dangerous over-pressure or cause nuisance lockouts. Because this is a compressor-protection device, matching OEM calibration is essential.
Moderate — recommended for HVAC technicians. Involves relieving/recovering refrigerant pressure at the access port, disconnecting the switch leads, and installing the replacement without introducing leaks. De-energize power first. EPA certification is typically required for any work touching the refrigerant circuit.