IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 0130M00074 High Pressure Cut-Off Switch is a genuine OEM safety control designed for the Goodman WGPH4536AMAB packaged air conditioner and compatible models. Wired into the compressor control circuit, this switch continuously monitors discharge-side refrigerant pressure and opens the circuit if pressure climbs to an unsafe level — protecting the compressor from damage caused by a dirty condenser coil, failed condenser fan, overcharge, or restricted airflow.
This is the factory OEM part, pre-calibrated to Goodman's exact cut-out and reset set points. Generic universal pressure switches may carry different trip thresholds and connection styles, which can lead to nuisance trips or a switch that never protects the compressor when it should. For a safety-critical control, OEM is the recommended choice.
Moderate. Requires disconnecting power, a Schrader-style or flare connection on a refrigerant port, and basic low-voltage wiring. Refrigerant handling on some configurations may require an EPA-certified technician. Plan 20–40 minutes.