IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 0130M00074 High Pressure Cut-Off Switch is a genuine OEM refrigerant safety control for the APH1624M41AB heat pump. Wired into the compressor control circuit, it continuously senses discharge-side pressure and opens the circuit if pressure climbs to an unsafe level — protecting the compressor and coil from rupture during a blocked condenser, failed fan, or overcharge condition. If your unit trips on high-pressure lockout or the compressor won't stay running on a hot day, a faulty high-pressure switch is a prime suspect.
The OEM Goodman switch is calibrated to the exact factory cut-out and cut-in pressure settings for this system. Generic switches may trip early (nuisance lockouts) or late (no protection at all). For a component whose entire job is safety, OEM calibration is not optional.
Moderate (3 of 5). Involves recovering/isolating refrigerant pressure at the port, swapping terminals, and leak-checking. Roughly 30–45 minutes. Refrigerant-circuit work should be performed by an EPA 608-certified technician.