IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The 0130M00074 is a genuine OEM high-pressure cut-off switch for the Goodman APH1436H41DD heat pump. Installed on the high (discharge) side of the refrigerant circuit, it opens the control circuit and shuts down the compressor if discharge pressure climbs to an unsafe level — protecting the compressor against a blocked condenser, overcharge, or a failed fan. When it trips prematurely or won't reset, cooling is lost and the compressor is at risk.
Genuine Goodman switches ship with the factory-calibrated trip and reset pressures and the correct fitting/connector for this model. Generic switches may carry a different setpoint or thread, causing nuisance trips or an unsafe cutoff point. For reliable compressor protection, use the OEM part.
Moderate (3/5). Involves the sealed refrigerant system — Schrader-fitting types swap without recovery, brazed types require EPA-certified recovery and evacuation. Recommended for a licensed HVAC technician. Disconnect power first.