IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 0130F00010S is a genuine OEM flame sensor (flame rod) for the AMSS960805CNAA gas furnace. This single-rod sensor uses flame rectification to confirm the burners have actually lit; if it detects no flame current within a few seconds of ignition, the control board closes the gas valve as a safety measure. A dirty, corroded, or failed flame sensor is the number-one cause of a furnace that lights and then shuts off after 3–7 seconds, repeatedly short-cycling into a no-heat lockout.
The genuine 0130F00010S uses the correct rod length, ceramic insulator, and mounting geometry so the tip sits properly in the flame envelope — critical for a reliable microamp signal. Aftermarket rods that sit too high or low in the flame produce a weak, drifting signal that causes intermittent lockouts. For a critical safety component, OEM is strongly recommended.
Easy (2/5) — about 10–15 minutes. Shut off power and gas, remove the single mounting screw, disconnect the sensor lead, and install the new rod. Do not touch the rod with bare fingers — skin oils reduce flame conductivity. Wipe with a clean cloth before start-up.