The Goodman 0130F00010S Flame Sensor is the genuine OEM flame-proving rod for the Amana/Goodman AMSS920803BNAA gas furnace. Through flame rectification, the sensor confirms that the burner has actually lit; if it fails to detect flame, the control board closes the gas valve within seconds. A dirty, corroded, or cracked flame sensor is the number-one cause of furnaces that light briefly and then shut off (short-cycle on ignition lockout).
The OEM 0130F00010S uses the correct rod length, bend, and insulator so it sits in the proper flame envelope and returns a strong microamp signal. Generic sensors with the wrong geometry often produce weak flame signal and nuisance lockouts. When ignition reliability matters, choose the OEM rod.
Easy (1/5). Turn off power, remove one mounting screw, pull off the single wire, and swap in the new sensor. Do not sand a new OEM rod — install it clean and dry. Handle only the ceramic base to avoid contaminating the sensing surface.