The 0130F00010S flame sensor is the OEM flame-rectification rod for your Goodman / Amana AMEC960803BNAB gas furnace. It confirms burner flame is present and signals the control board to keep the gas valve open. When the rod oxidizes or cracks, the furnace lights then shuts down after a few seconds — the classic flame-sense failure that causes short-cycling and no-heat lockouts.
The OEM Goodman sensor uses the correct rod length, bend, and insulator so it sits properly in the flame for a strong microamp signal. Generic rods may misposition in the flame and produce weak, unstable readings that trigger lockouts.
Easy (2/5). One screw and one wire; 10–15 minutes. Disconnect power first. Tip: gently clean or replace at annual service to prevent flame-sense faults.