IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The genuine Goodman 0130F00010S flame sensor confirms that a flame is present during the heating cycle on the Goodman GMPH050-3 and compatible furnaces. Using flame rectification, it signals the control board to keep the gas valve open only when combustion is verified — a core safety function. A dirty or failed flame rod is one of the most frequent causes of short-cycling and no-heat lockouts.
The genuine Goodman sensor matches the exact rod length, bracket angle, and terminal your burner assembly requires for a correct microamp signal. Generic sensors may sit at the wrong position in the flame and produce weak or erratic readings, causing nuisance lockouts. OEM ensures a stable signal and proper safety operation.
Rating: Easy. Typically a single mounting screw and one push-on wire. Shut off power and gas, remove the old rod, install the new one, and restore power. A confident homeowner can complete this in minutes; verify flame signal if a meter is available.