The Goodman 0130F00010S flame sensor is the genuine OEM flame-rectification rod for GCH950703BXAA gas furnaces. It confirms flame presence to the control board via a micro-amp signal; when the rod becomes oxidized or cracked, the furnace ignites and then shuts down within seconds — the classic short-cycling / no-heat lockout. Replacing a worn sensor with the correct factory part is the single most common fix for intermittent Goodman furnace ignition faults.
This genuine Goodman OEM sensor is built to the exact rod length, bend, and insulator spacing the GCH95 burner requires for a stable flame-current reading. Generic sensors may sit too far from the flame or short against the manifold, producing weak signals and repeat lockouts. The OEM part delivers a clean, reliable micro-amp signal.
Easy (1/5). Cut power, remove the single mounting screw, unplug the sensor lead, install the new rod, and reconnect. Typical replacement time is 10–15 minutes with a 1/4" nut driver. Do not sand or touch the new rod with bare fingers.