IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 0130F00010S Flame Sensor is a genuine OEM flame-rectification rod for the GCH90704CXAB gas furnace and compatible Goodman/Amana models. The flame sensor confirms burner ignition to the control board via micro-amp flame current; a dirty or failed sensor is the #1 cause of furnaces that light briefly then shut down (short-cycling) or lock out on ignition failure.
The OEM 0130F00010S uses the correct rod length, alloy, and bracket bend to sit precisely in the burner flame path. Generic sensors often mis-position the rod, producing weak flame current and intermittent lockouts even when new. OEM ensures a stable signal and reliable ignition all season.
Easy (2 of 5). Turn off gas and power, remove one mounting screw, unplug the wire lead, and install the new sensor. No wiring changes required. Tip: if a furnace still short-cycles after replacement, check for corrosion at the control-board connector. Typical job time is 15–20 minutes.
Genuine Goodman part with a fit guarantee. Email your model and serial to info@nationalhvacparts.com if you need help confirming compatibility.