IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The 0130F00010S is a genuine Goodman OEM flame sensor (flame rod) for the AMVM971005CNAA modulating variable-speed gas furnace. This single-rod sensor uses flame rectification to confirm the burner has lit: it passes a micro-amp signal through the flame to the control board. If the board sees no flame current within the trial-for-ignition window, it shuts the gas valve for safety. A dirty, corroded, or worn flame sensor is the single most common cause of a furnace that lights briefly and then shuts off, or that locks out after several failed ignition attempts.
Flame current is measured in microamps, so rod length, position, and material directly affect the reading. The genuine Goodman 0130F00010S delivers the exact geometry and alloy the control board expects, restoring a strong, stable flame signal. Cheap universal rods often produce marginal signals that cause intermittent lockouts down the road.
Easy (1/5). Turn off power and gas, remove one mounting screw, unplug the wire, and swap in the new sensor — avoid touching the rod with bare hands. Reassemble and test for steady flame. A common 15-minute DIY repair.
In stock and shipping fast from National HVAC Parts.