The Goodman 0130F00010S is a genuine OEM flame sensor for the Amana/Goodman AMVC80905CXAB two-stage variable-speed gas furnace. This flame-rectification rod confirms to the control board that the burners have lit; if it fails to detect flame, the board shuts off gas as a safety measure. A dirty, oxidized, or cracked flame sensor is a leading cause of short cycling and intermittent no-heat — the factory part restores reliable flame proving.
The OEM 0130F00010S uses the correct rod length, alloy, and bracket geometry to sit precisely in the flame envelope, producing a strong, stable microamp signal. Generic sensors may sit at the wrong depth or angle, causing weak signal and nuisance lockouts even when clean. For dependable flame proving, choose OEM.
Easy — 1 of 5. Shut off power, remove the single mounting screw, unplug the wire lead, and install the new sensor — avoid touching the metal rod with bare fingers. Reconnect and run a full heat cycle to confirm steady operation. One of the simplest furnace repairs.