The genuine OEM Goodman 0130F00010S flame sensor is the flame-rectification rod for the AMVC800805CNAB 80% AFUE two-stage furnace. It confirms the burner has lit by passing a small microamp current through the flame; when that signal weakens from oxidation or carbon buildup, the control board can no longer prove flame and shuts the gas valve. The classic symptom is a furnace that lights, runs a few seconds, then drops out and re-tries — repeated short-cycling and eventual lockout. Installing a clean OEM sensor is the most common fix for flame-loss faults.
The OEM 0130F00010S uses the correct rod length, bend, and insulator rating so the sensing rod sits properly in the flame envelope. Generic rods that sit too high or low give erratic microamp readings and can mimic the very fault you are trying to fix. For a sensing component, the factory geometry matters.
Easy — typically one screw and a single spade connector. Shut off power, remove the old sensor, seat the new one, and reconnect. Do not sand a brand-new sensor. Verify a steady flame and no short-cycling on the first heat call.