The 0130F00010S Flame Sensor is a genuine OEM flame-proving rod for the Goodman/Amana AMVC800804CXAA gas furnace. The flame sensor confirms the burner has lit by detecting the microamp current that flows through an established flame, allowing the control board to keep the gas valve open. A dirty, corroded, or failed sensor is one of the most common causes of a furnace that lights briefly and then shuts down.
This genuine OEM sensor uses the correct rod length, mounting bracket, and terminal so flame current reads within factory spec on the first cycle. Generic sensors often require bending or adapters and can produce erratic microamp signals that trigger nuisance lockouts.
Easy — Shut off power, remove one mounting screw and the sensor wire, and swap. A 10-minute repair for most DIYers; avoid touching the rod with bare fingers.