IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 0130F00010S Flame Sensor is a genuine OEM ignition-safety component for the Goodman/Amana AMSS960603BNAA gas furnace. This single-rod sensor uses flame rectification to confirm that the burners have actually lit: it carries a microamp signal through the flame back to the control board. If no flame is detected within seconds of ignition, the board closes the gas valve — preventing raw gas from accumulating. A dirty, corroded, or cracked flame rod is the single most common cause of a furnace that lights briefly then shuts off (short-cycling on flame failure).
OEM vs. Generic: The rod length, bend, and porcelain insulator must place the tip correctly in the flame envelope. The OEM 0130F00010S is shaped to seat exactly in the AMSS960603BNAA burner assembly. Generic sensors that sit too shallow read a weak microamp signal and cause nuisance lockouts. For reliable ignition, use the genuine Goodman sensor.
Install Difficulty: ⭐⭐ Easy (2/5) — power down, remove one mounting screw, unplug the sensor wire, and install the new rod. Avoid touching the porcelain with bare fingers. A DIY-friendly repair; always shut off power and gas first.