IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 0130F00010S is the genuine OEM flame sensor (flame rod) for the AMSS960402BNAA gas furnace and many compatible Goodman and Amana models. Positioned in the burner flame, this sensor uses flame-rectification to confirm ignition to the control board. When the rod becomes coated with silica or carbon, the microamp signal drops and the board shuts the gas valve as a safety response — the classic symptom is a furnace that lights, runs briefly, then shuts off and short-cycles. Replacing a worn or oxidized flame sensor is one of the most common and effective no-heat repairs.
The OEM 0130F00010S uses the correct rod length, bend, and Kanthal alloy so the flame envelope covers the sensor exactly as designed, delivering a strong, stable flame-current signal. Generic sensors may sit too high or low in the flame, producing marginal readings and repeat lockouts. Genuine OEM ensures a reliable first-time fix.
Easy (1/5). Shut off power, remove the single mounting screw, unplug the sensor wire, and install the new rod. Do not clean the new sensor with sandpaper — its coating is factory-set. Most installs finish in under 10 minutes.