IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 0130F00010S Flame Sensor is the genuine OEM flame rectification rod for AMH81205DXAA gas furnaces and compatible Goodman/Amana models. This sensor confirms the presence of a flame during the ignition sequence; when it becomes coated with oxide or carbon, the control board can no longer detect the microamp signal and shuts the burners down as a safety measure. Replacing a weak or fouled sensor is the single most common fix for short-cycling, delayed ignition, and hard-lockout faults.
The genuine OEM 0130F00010S is manufactured to Goodman's exact rod length, insulator spec, and terminal geometry, guaranteeing correct flame-current readings and a clean mechanical fit. Universal aftermarket sensors often require rod bending or adapter brackets and can produce erratic microamp readings that trip nuisance lockouts. For a reliable, drop-in repair we recommend the OEM part.
Rated Easy — a 5–10 minute job for most homeowners. Shut off power and gas, remove the single mounting screw, unplug the wire lead, and reverse. Clean the burner area before installing. No calibration required.