The Goodman 0130F00010S is a genuine OEM flame sensor (flame rod) for the Amana AMES801205DXAA 80% AFUE gas furnace and compatible Goodman/Amana models. Positioned in the burner flame, the sensor uses flame rectification to confirm to the control board that the burners have actually lit. When the rod oxidizes or cracks, the board can no longer prove flame and shuts the gas valve within seconds — the single most common cause of a furnace that lights briefly then short-cycles into a no-heat lockout.
The OEM 0130F00010S uses the correct rod length, bend, and Kanthal alloy so the flame fully envelops the tip and produces a strong, stable microamp signal. Generic sensors often sit at the wrong depth in the flame, yielding a weak signal that triggers intermittent lockouts. Given the low cost, genuine OEM is the reliable fix.
Rating: Easy (1/5). Kill power at the furnace switch, remove one screw, unplug the wire, and install the new rod — about 10 minutes. Tip: lightly clean the burner ground and verify a flame-current reading (typically 2–6 µA) if your meter supports it before closing up.