IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman/Amana 0130F00010S flame sensor confirms the presence of a burner flame during each heating cycle. It uses flame rectification to send a small microamp signal to the control board; if the board doesn't detect that signal, it shuts off the gas valve for safety. A dirty or failed flame sensor is one of the most common causes of a furnace that lights briefly then shuts down (short cycling). This genuine OEM sensor is the exact fit for the AMEC960603BNBA and matching Goodman/Amana furnaces.
The OEM 0130F00010S is built with the correct rod length, alloy, and mounting bracket for reliable flame rectification in this furnace. Generic sensors may produce a weaker or unstable microamp signal, leading to intermittent lockouts. For dependable ignition, the genuine OEM part is recommended.
Rating: Easy. Turn off power and gas, remove one mounting screw and the wire, and install the new sensor. This is one of the most DIY-friendly furnace repairs — typically 10–15 minutes with a single nut driver.