IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 0130F00010S Flame Sensor is a genuine OEM flame-rectification rod for the Amana/Goodman AMEC960403ANAB gas furnace. The sensor confirms the burner has actually lit by detecting the microamp current that flows through an active flame. When the sensor becomes coated with oxide or fails, the control board can't verify flame and shuts the gas valve — producing the classic symptom of a furnace that lights briefly then shuts off (short cycling) or locks out with no heat.
OEM sensors use the correct rod length, alloy, and mounting bracket so the flame fully envelops the tip for a strong, stable signal. Generic sensors sometimes read a weak microamp value that causes intermittent lockouts. Given how central this part is to reliable ignition, genuine OEM is the dependable choice.
Beginner (2/5). Shut off power, remove one mounting screw and the single wire connector, and swap in the new sensor. Avoid touching the metal rod with bare hands — oils reduce the signal. A one-screw job that resolves most no-heat and short-cycling calls.