The Goodman 0130F00010S Flame Sensor is the genuine OEM flame-rectification rod for the Goodman ACVC90704CXAB 96% AFUE two-stage gas furnace. After ignition, the control board sends a small AC signal through this sensor; the flame conducts a tiny microamp DC current back to the board, proving the burner is lit. When the sensor oxidizes or cracks, the board can no longer confirm flame and shuts the gas valve within seconds — producing the classic symptom of a furnace that lights, runs briefly, then short-cycles or locks out with a no-heat call.
The OEM 0130F00010S uses the correct rod length, mounting bracket, and terminal so it sits at the precise flame position the burner was designed for — critical for a strong, stable microamp signal. Generic flame sensors often differ slightly in rod length or bracket angle, which can read a weak flame current and bring back the same short-cycling you are trying to fix. Genuine ensures a reliable signal and full board compatibility.
Easy (2 of 5). Roughly 15–20 minutes. Turn off power and gas, remove the single mounting screw, disconnect the sensor lead, and install the 0130F00010S. Avoid touching the rod with bare fingers. Restore power and gas, then confirm a steady flame and proper microamp reading on startup.