The Goodman 0130F00010S is a genuine OEM flame sensor built for the ACSH960904CXAA high-efficiency gas furnace. This flame-rectification rod confirms that the burners have lit during each heat cycle; if it fails to detect flame, the control board closes the gas valve for safety. A dirty, corroded, or failing sensor is the most common cause of furnaces that ignite then shut off after a few seconds (short cycling) or drop into ignition lockout.
The genuine Goodman OEM sensor uses the correct rod length, alloy, and bracket so it sits in the proper position within the burner flame for a strong, stable microamp signal. Generic sensors often mount at the wrong depth or use lower-grade rods that foul quickly, leading to repeat short-cycling complaints. For reliable flame proving on the ACSH960904CXAA, the OEM rod is the dependable fix.
Easy to Moderate (2/5). Shut off power and gas, remove one mounting screw, unplug the spade connector, and install the new sensor in the same orientation. Most installs take 15–20 minutes. Avoid touching the rod with bare fingers to prevent oils from fouling the surface.