IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The 10135604 is a genuine Goodman control relay for the GCG300360EBXXXAA furnace and compatible Goodman/Amana gas units. This relay uses a low-voltage control signal to switch the higher-current blower and heating circuits on and off, coordinating fan and heat operation with the thermostat's demand. Relay contacts wear and pit over time, leading to intermittent operation, a blower that won't start or won't stop, chattering, or no heat at all — replacing the relay restores dependable, quiet switching.
The OEM 10135604 is rated for the exact coil voltage, contact amperage, and terminal layout the GCG300360EBXXXAA control sequence expects. Generic relays may differ in pinout or contact rating, causing miswiring or premature failure. OEM ensures a drop-in, correctly-rated fit.
Moderate (3/5). Disconnect power, photograph or label each wire, transfer connections one at a time to the identical terminal, and secure the relay. Verify blower and heat cycling after power-up.