The Goodman 20171701 condensate drain trap collects and drains the acidic condensate produced by the secondary heat exchanger of the ACSH960905DXAA 96% AFUE furnace. It maintains a water seal that blocks flue gases from escaping the drain line while allowing condensate to flow away. A cracked or clogged trap causes water leaks, pressure-switch faults, and nuisance lockouts.
OEM Goodman traps match the exact port locations, internal baffles, and hose-barb sizes of the factory unit, so they seat correctly and seal the pressure-switch tubing. Generic universal traps often require adapters and can trigger pressure-switch errors. OEM ensures a clean, leak-free fit.
Moderate — involves disconnecting condensate and pressure-switch hoses and clearing the drain line. Power down the furnace, label hoses before removal, and prime the new trap with water to establish the seal before restart.