The Goodman/Amana 0130F00010S Flame Sensor is the OEM flame-rectification sensor for the AMH81005CNBA 80% AFUE gas furnace and compatible Goodman/Amana models. The flame sensor confirms to the control board that the burners have actually lit; when its microamp signal falls below threshold — usually from oxidation or carbon buildup on the rod — the board shuts the gas valve within seconds as a safety response. This is the single most common cause of a furnace that lights, runs briefly, then shuts off and locks out (short-cycling / repeated ignition attempts).
OEM vs. Generic: The genuine 0130F00010S uses the correct rod length, alloy, and bracket geometry so it sits precisely in the flame envelope for a stable signal. Generic sensors often mount at a slightly different angle or depth, producing a weak or erratic microamp reading and continued lockouts. For reliable flame proving, OEM is the safe bet.
Install difficulty: Easy (1/5). One screw and one wire — typically a 10-minute swap. Shut off power and gas first. Tip: if your current sensor is only lightly fouled, a gentle cleaning may restore it, but a pitted or cracked rod should be replaced.