IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman/Amana 20197312 Air Pressure Switch is a genuine OEM safety control for the AMH950704CXAC gas furnace. Calibrated at -0.37 in. w.c. and wired normally open (NO), it verifies correct inducer draft before the furnace is allowed to ignite, protecting against blocked vents, cracked heat exchangers, and unsafe combustion.
When this switch fails or drifts out of calibration, the furnace typically locks out on a pressure-switch fault and will not fire. Replacing it with the exact OEM part restores proper ignition sequencing and safe operation.
Pressure switches are safety devices — the trip point must match your furnace's engineered draft. This OEM switch is factory-set to -0.37 in. w.c. with the correct hose barb and terminal layout. Generic switches with the wrong set point can allow unsafe firing or cause false lockouts and are not recommended for a safety circuit.
Easy to Moderate (2 of 5). Cut power, note wire and hose positions, remove the mounting screws, and transfer the tubing and spade connectors to the new switch. Takes 15–25 minutes with basic tools. If the furnace still faults, inspect the tubing and inducer for blockage.
Genuine OEM reliability for safe, dependable heating.