IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The genuine OEM 0130F00506 air pressure switch is a critical draft-proving safety for the Goodman/Amana VMES800603AXAA furnace. Rated at -0.75 inches of water column, normally open, it verifies that the inducer/vent motor is producing adequate draft before the control board allows ignition. If venting is blocked or the inducer is weak, the switch stays open and safely prevents the burners from firing — avoiding dangerous flue-gas conditions.
Pressure switch calibration must match your furnace's designed draft. The OEM 0130F00506 is factory-set to the exact -0.75" WC threshold. Generic switches with approximate setpoints can cause nuisance lockouts or fail to prove draft correctly, so OEM is strongly recommended for safety-critical components.
Easy (2/5). Cut power, photograph the hose and wire connections, remove the mounting screw(s), and transfer the tubing and terminals to the new switch. Inspect the hose for cracks or condensate blockage while replacing. About 15 minutes.