IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 20197312 Air Pressure Switch is a genuine OEM -0.37 in. WC, normally open (NO) draft-proving control for the Goodman GMS950704CXA 96% AFUE condensing gas furnace and compatible GMS95-series models. Connected to the induced-draft blower, this switch confirms that the vent system is drawing correctly before the control board allows ignition. If the required negative pressure isn't reached — from a blocked flue, condensate backup, or weak inducer — the switch keeps its contacts open and safely prevents burner light-off.
Pressure-switch set point and contact type are calibrated to this furnace's inducer and vent design. This OEM switch trips at exactly -0.37 in. WC with the correct NO contacts, so venting is proven precisely as certified. A generic switch with the wrong set point or NC contacts can allow unsafe operation or cause chronic pressure-switch lockouts. Match the rating exactly.
Moderate (2 of 3). Power off, note and transfer the pressure hose(s) and spade terminals to the new switch, and remount. Inspect the hose and inducer port for condensate or blockage while you're in there. A 20–30 minute repair.