The Goodman 11177113 is a genuine OEM dual (combination) draft pressure switch for the two-stage WGFM295070V4CAA gas furnace. It combines two set points — -.30" WC and -.75" WC — in one gray housing to prove adequate inducer draft on both low-fire and high-fire stages before the control board allows ignition. A failed or drifted pressure switch is one of the most common causes of a furnace that clicks but won't light, or that short-cycles on stage changes.
Pressure switch calibration is safety-critical — the set points must exactly match the furnace's designed inducer draft. The genuine Goodman 11177113 is factory-calibrated to the -.30"/-.75" WC spec. Generic switches with approximate set points can allow ignition under weak-draft conditions or lock out a healthy furnace. For a safety proving device, use the OEM part.
Moderate (3/5) — Power off, photograph the hose and wire routing, then transfer the pressure tubing and spade connectors to the new switch in the same positions. Confirm no pinched or cracked hoses. Test firing on both stages after install.