IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 11177113 Combination Pressure Switch is a genuine OEM dual-stage draft-proving control for the GMV950453BXAB two-stage 95% AFUE gas furnace. It combines two set points — -0.30 in WC and -0.75 in WC — in a single gray housing, verifying correct inducer draft on both low-fire and high-fire stages before the ignition sequence is allowed to proceed. If venting is blocked or the inducer is weak, the switch prevents ignition, protecting against unsafe combustion.
Pressure-switch set points are model-specific and safety-critical. The exact -0.30/-0.75 in WC calibration and dual-port gray body on this genuine Goodman switch cannot be reliably matched by a universal part. An incorrect set point causes nuisance lockouts (Code 6/pressure-switch faults) or, worse, allows firing under poor draft. Always replace with the exact OEM number.
Moderate — Shut off power, label and transfer the pressure tubing to the correct ports, and reconnect the wiring harness. Confirm tubing is free of condensate and firmly seated. Estimated time: 20–30 minutes. Recommended for experienced DIYers or a licensed technician.
Genuine OEM part backed by same-day shipping on in-stock orders.