The Goodman 11177113 Combination Pressure Switch is a genuine OEM dual-stage safety control for the GMV950453BXBA two-stage variable-speed gas furnace. It monitors inducer draft on both firing stages, closing at -0.30 in WC (low stage) and -0.75 in WC (high stage) to confirm proper venting before the gas valve is allowed to open.
OEM vs. Generic: A pressure switch is a life-safety device — its setpoints must match the furnace vent design exactly. The OEM 11177113 is factory-calibrated to both stages; a mismatched generic can allow ignition under blocked-vent conditions or cause chronic lockouts. Always use OEM for combustion safety controls.
Install difficulty: Moderate (3/5). Disconnect power, label and transfer the wiring and hose(s) to the matching ports, then mount the new switch. Verify low- and high-stage operation with a manometer after install. A licensed technician is recommended.