The Goodman 10135604 Relay is a genuine OEM replacement for the ASH130421AC heat pump. This electromechanical relay uses a low-voltage control signal to switch a higher-current load — typically the condenser fan, compressor circuit, or an auxiliary output on the outdoor unit. Symptoms of a failed relay include a component that won't energize, chattering contacts, or intermittent operation as the contacts pit and burn.
The Genuine OEM Goodman relay matches the factory coil voltage, contact rating, and terminal configuration for drop-in replacement. Generic relays with a different pinout or contact amperage can weld shut or fail early under compressor inrush. Choosing OEM avoids rewiring and ensures the contacts are rated for this unit's load.
Easy (2/5). Most relays are push-on or single-screw mounted with spade terminals. De-energize the unit at the disconnect, photograph and transfer the wires to matching terminals, and confirm the coil is a true 24V match. A straightforward repair for a careful DIYer, though a technician can verify the relay — not an upstream control — is the actual fault.