The Goodman 20197308 Pressure Switch is a genuine OEM normally-open (NO) air-proving switch rated at -0.10 in. WC for the Goodman/Amana AMV90453BXAB gas furnace. This switch verifies that the induced-draft blower has established proper airflow before the control board energizes ignition. When the inducer pulls the required negative pressure, the normally-open contacts close, proving draft; if draft is insufficient — from a blocked flue, weak inducer, or plugged pressure port — the switch stays open and safely prevents the burner from firing.
OEM vs. Generic: The OEM switch is factory-calibrated to the exact -0.10 in. WC trip point and matches the furnace's connector and mounting. Generic switches with approximate set points can cause pressure-switch lockout codes or, worse, prove draft when it isn't truly present. For a combustion-safety control, OEM calibration matters.
Install difficulty: Easy. Disconnect the low-voltage wire harness and the rubber pressure hose, unscrew the switch from its bracket, and reverse to install — about 15 minutes. Confirm the hose is seated with no cracks and verify with a manometer if possible. Always disconnect power before service.