IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 20197308 is a genuine OEM air-proving pressure switch calibrated to actuate at -0.10 inches of water column (negative pressure) with a normally open (NO) contact configuration. It is the correct switch for the AMVC950905CXBA high-efficiency variable-speed furnace. This safety control confirms that the induced-draft blower is moving combustion air and venting exhaust properly before the ignition sequence begins — if adequate draft is not proven, the switch prevents the gas valve from opening.
Pressure switch calibration is safety-critical. The OEM 20197308 is factory-set to the exact -.10" WC trip point your furnace's control board expects. Generic or mismatched-set-point switches can allow ignition without proven draft or cause repeated lockouts. Always match the OEM set point and NO/NC configuration.
Plan on 20–40 minutes. Shut off power and gas, photograph the wiring and tubing, transfer the sensing hose to the same port orientation, and mount the new switch. Verify correct operation with a manometer if available. Because this is a combustion-safety component, have a qualified HVAC technician confirm the installation.
Genuine Goodman OEM safety part. Fits AMVC950905CXBA.