IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 20197308 is a genuine OEM air-proving pressure switch engineered for the AMH950703BXAG 96% AFUE gas furnace and compatible Goodman/Amana models. This normally-open switch monitors draft-inducer airflow and closes at a -.10" WC setpoint, proving proper venting before the ignition sequence begins. A failed or drifting pressure switch is one of the most common causes of a furnace that ignites and then locks out, or won't start at all.
This is a factory-original Goodman/Amana component built to the exact pressure tolerance your control board expects. Generic replacements often use approximate setpoints that trigger nuisance lockouts or unsafe operation. For a safety-rated switch, OEM is the recommended choice — pair it with a matching switch tube grommet if yours is aged or cracked.
Moderate. Replacement takes 20–40 minutes with basic hand tools. Cut power at the disconnect, disconnect the wiring and the rubber pressure tube, remove the mounting screws, and transfer the tube to the new switch in the same orientation. Verify the tube is clear of condensate. Professional installation is recommended if you are not comfortable working around gas appliances.