IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 20197308 is a genuine OEM air-proving pressure switch calibrated to a -0.10 inch WC setpoint and wired normally open (NO). It confirms adequate venting/draft before the furnace control board permits ignition, and on two-stage systems like the Goodman WGFM295090V5DAA it works alongside the higher-stage switch to prove airflow at low fire. A faulty switch commonly shows up as no-heat, lockout, or venting-related fault codes.
Because this switch trips at a low -.10" WC setpoint, calibration accuracy is essential. Our OEM Goodman switch is factory-set to the exact specification the control board expects, avoiding the nuisance lockouts or false proving that off-spec generic switches can cause. For a safety-critical combustion control, the genuine OEM part is the right choice.
Moderate — Disconnect the tubing and wiring, remove the mounting screws, and transfer the hose to the new switch. Verify the -.10" WC rating and configuration before installing, and confirm operation with a manometer where possible. Shut off power before servicing; technician-level task.