The Goodman 20197308 Pressure Switch is a genuine OEM draft-proving safety control for the GMH951155DXAG gas furnace, rated at -0.10 in. w.c. with normally-open (NO) contacts. Connected to the induced-draft blower, this switch confirms proper venting airflow before the ignition sequence begins — closing its contacts only when the correct negative pressure is sensed. If draft is blocked or the inducer fails, the switch stays open and locks out the furnace, preventing dangerous combustion. A weak diaphragm or off-spec switch is a leading cause of no-ignition and lockout codes.
OEM (20197308): Factory-calibrated to the exact -0.10" set point and tube-port layout this furnace needs — critical, since an incorrect set point defeats the safety function. Strongly recommended.
Generic: Aftermarket switches must match the exact pressure rating, contact configuration, and hose fitting. Never substitute a different set point on a safety control.
Easy (2/5). Power down the furnace, note the wiring, disconnect the two spade terminals and the rubber sensing hose, unscrew the bracket, and install the new switch. About 15–20 minutes. Confirm the -0.10" rating printed on the switch matches the original.