IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 20197308 Pressure Switch is a genuine OEM draft-proving control for the WGFM295115V5DAA variable-speed 96% AFUE gas furnace. This normally-open switch is calibrated to -.10 inch water column (WC) and confirms the correct low-fire (first-stage) inducer pressure before the control board permits ignition. On two-stage furnaces like the WGFM295, multiple pressure switches verify draft at each firing rate for safe, staged operation.
The OEM 20197308 is set to the precise -.10 in WC threshold the WGFM295 low-fire sequence expects. A generic switch with a different set point can cause failure-to-ignite, short cycling, or improper stage proving. As a combustion-safety device, the genuine Goodman part is the recommended replacement.
Easy — cut power, note wire positions, unplug the spade terminals, remove the mounting screws, and transfer the silicone tubing to the new switch in the same orientation. Clear any condensate from the tubing and verify operation on a heat call.