IMAGE COMING SOON
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
The Goodman 0130F00002P is a genuine OEM combustion air pressure switch calibrated at -0.95 inches of water column (WC), normally open (NO), for the GMH950703BXAF and related 95% AFUE furnaces. This safety switch monitors draft from the induced-draft blower and closes only when adequate venting is confirmed, allowing ignition to proceed. If draft is insufficient — from a blocked flue, failing inducer, or condensate backup — the switch stays open and prevents burner operation, protecting against unsafe combustion.
Pressure switches are setpoint-specific — using a switch with a different trip pressure will cause chronic lockouts or, worse, allow operation without proper draft. This genuine Goodman part is factory-calibrated to the exact -0.95" WC specification and uses the correct port and terminal configuration, so it proves draft reliably. Generic substitutes with approximate ratings frequently trigger nuisance codes.
Rating: Easy to Moderate. The switch mounts with one or two screws and connects via a hose to the inducer and two spade terminals. Photograph the hose and wire routing before removal. Shut off power before servicing and verify the correct setpoint stamped on the old switch matches before installing.